What Are Sling Pneumatic Fenders

The sling pneumatic fender is basically the same yokohama fender, but without the outer protective netting. They are also built in three layers: outer rubber layer, synthetic-cord layer for reinforcement and the inner rubber layer. The sling type fenders have much stronger and thicker outer rubber layer, resulting in better resistance to operational damages. A flange with shackle and swivel is mounted to which a chain or cable can be attached at each end of the fender. The sling yokohama fenders can be inflated and deflated multiple times with no problem for easy deployment, transporting to a different location or for storage.

Get a Quote

Sling Type Fender Features

1.Wide range of applications for ship to ship (STS) / ship to berthing (STB) / ship to quay (STQ).
2.Very low reaction and high energy absorption.
3.Suitable for areas with tidal difference.
4.Easy to inflate and fast to install, low maintenance and low transportation costs.
5.Temporary and permanent installations.
6.Manufactured in accordance with the ISO17357:2014

Sling Pneumatic Fender Technical Parameter

Table 1 — Pneumatic 50 fender size and performance requirements
Nominal size diam_x001f_eter x length mmInitial internal pressure kPaGuaranteed energy absorption (GEA)Reaction force at GEA deflection (R)Hull pressure (Internal pressure) at GEA deflection (P)
Minimum value at deflection 60 ± 5 % kJTolerance ±10 % kNReference value kPa
500 x 100050664132
600 x 100050874126
700 x 15005017137135
1000 x 15005032182122
1000 x 20005045257132
1200 x 20005063297126
1350 x 250050102427130
1500 x 300050153579132
1700 x 300050191639128
2000 x 350050308875128
2500 x 4000506631 381137
2500 x 5500509432 019148
3300 x 4500501 1751 884130
3300 x 65005018143015146
3300 x 106005030675257158
4500 x 90005047525747146
4500 x 120005064737984154
Table 2 — Pneumatic 80 fender size and performance requirements
Nominal size diameter × length mmInitial internal pres-sure kPaGuaranteed energy absorption (GEA)Reaction force at GEA deflection (R)Hull pressure (Internal pressure) at GEA deflection (P)
Hull pressure (Internal pressure) at GEA deflection (P)Tolerance ±10 % kNReference value kPa
500 x 1 00080885174
600 x 1 000801198166
700 x 15008024180177
1 000 x 2 0008063338174
1200 x 20008088390166
1 350 x 250080142561170
1 500 x 300080214761174
1 700 x 300080267840168
2000 x 3500804301150168
2 500 x4 000809251815180
2 500 x 5 5008013172653195
3300 x45008016402476171
3300 x 65008025323961191
3 300 x 10 6008042816907208
4 500 x9 0006633807551192
4 500 x 12 00080903710490202

Get a Quote